Many different sampling methods were tested and compared for collecting samples for measurement of brine chemistry, gases, and suspended solids from pressurized geothermal systems. The tests were conducted on the 6-2 wellhead and a test loop at the Department of Energy's Geothermal Test Facility at East Mesa, California. The recommended methods for single-phase liquid or single-phase steam (with gases) are presented, together with detailed procedures. The results of testing methods for sampling two phase liquid-steam systems showed significant errors can result. It was recommended that two-phase flowing wells be directed to a full flow separator and the single-phase liquid and single-phase steam sampled separately using the recommended methods; PNL-3412